EasyManuals Logo

Cisco VG450 User Manual

Cisco VG450
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
After you install the voice gateway, you must connect the chassis to a reliable earth ground. For the chassis
ground connection procedures, see the Chassis Grounding section.
Chassis Grounding
To reduce the risk of electric shock, the chassis of this equipment needs to be connected to permanent earth
ground during normal use. Statement 445
Warning
Use a size 10 AWG (4 mm2) or larger copper wire and an appropriate user-supplied ring terminal with an
inner diameter of 1/4 in. (5–7 mm).
To install the ground connection for your router, perform the following steps:
SUMMARY STEPS
1. Strip one end of the ground wire to the length required for the ring terminal.
2. Crimp the ground wire to the ring terminal, using a crimp tool of the appropriate size.
3. Attach the ground lug or ring terminal to the chassis as shown in the following image. Use one of the
screws provided. Tighten the screws to a torque of 8 to 10 in-lb (0.9 to 1.1 N-m).
4. Connect the other end of the ground wire to a known reliable earth ground point at your site.
DETAILED STEPS
Step 1 Strip one end of the ground wire to the length required for the ring terminal.
Step 2 Crimp the ground wire to the ring terminal, using a crimp tool of the appropriate size.
Step 3 Attach the ground lug or ring terminal to the chassis as shown in the following image. Use one of the screws provided.
Tighten the screws to a torque of 8 to 10 in-lb (0.9 to 1.1 N-m).
Installing the Cisco VG450 Voice Gateway
10
Installing the Cisco VG450 Voice Gateway
Chassis Grounding

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco VG450 and is the answer not in the manual?

Cisco VG450 Specifications

General IconGeneral
Power SupplyInternal AC power supply
Form Factor1RU
MountingRack-mountable
Operating Temperature32 to 104°F (0 to 40°C)
Humidity10% to 90% non-condensing
ProtocolsSIP, MGCP
Storage Temperature-4°F to 149°F (-20°C to 65°C)
Network Interfaces4 x 10/100/1000 Ethernet ports