CT-S4000 Service Manual
17
Faulty auto cutter
Phenomenon Cause Check Method Remedy
Faulty connection of the
auto cutter connector
Check the connecting
condition of the auto
cutter connector.
Connect the connector
correctly.
Failure in auto-cutter’s
main unit
Use tester or
oscilloscope or other
instrument to measure
supply voltage.
If the supply voltage is
normal, replace the auto
cutter.
No operation of
auto-cutter
Paper feed failure
(Paper jam)
Check that no paper is
jammed, torn or caught in
the paper path.
Remove unnecessary
paper and set correctly.