Citrix ADC MPX
1 sh raid
2 <!--NeedCopy-->
Output:
1 RAID1 status: READY
2 Drive:
3 1 ONLINE
4 2 ONLINE
5 Done
6 <!--NeedCopy-->
If both the SSDs’ show ONLINE and the RAID status shows READY, no action is required.
In the following table, the values in the first column show the drive number on the back panel of the
appliance. The drive number in the other columns refers to the number that must be used in the
command or as it appears in the output of the CLI and shell.
Chassis CLI command Shell command Shell command Shell command
Slot in chassis sh raid atacontrol
status ar0
atacontrol
detach /
atacontrol
attach
atacontrol
addspare ar0
SSD 1 drive 1 drive 0 ata2 ad4
SSD 2 drive 2 drive 1 ata3 ad6
The following output indicates SSD 2 has failed and must be replaced.
Command:
1 sh raid
2 <!--NeedCopy-->
Output:
1 RAID1 status: DEGRADED
2 Drive:
© 19992022 Citrix Systems, Inc. All rights reserved. 112