EasyManua.ls Logo

Citrix ADC MPX 5550 - Page 113

Citrix ADC MPX 5550
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Citrix ADC MPX
3 1 ONLINE
4 2 MISSING
5 Done
6 <!--NeedCopy-->
Sometimes, the failed drive/SSD might not be reported.
Command:
1 sh raid
2 <!--NeedCopy-->
Output:
1 RAID1 status: DEGRADED
2 Drive:
3 1 ONLINE
4 Done
5 <!--NeedCopy-->
From the shell, confirm that drive 1/SSD 2 has failed, RAID status reports DEGRADED and drive 1/SSD
2 reports MISSING, or not present in the output.
1. At the Citrix ADC command prompt, switch to the shell prompt. Type: shell
2. Check the status of the RAID array. SSD2 shows missing or is not present in the output.
Command:
1 root@ns# atacontrol status ar0
2 <!--NeedCopy-->
Output:
1 ar0: ATA RAID1 status: DEGRADED
2 subdisks:
3 0 ad4 ONLINE
4 1 ---- MISSING
5 <!--NeedCopy-->
© 19992022 Citrix Systems, Inc. All rights reserved. 113