OR
1 ar0: ATA RAID1 status: DEGRADED
2 subdisks:
3 0 ad4 ONLINE
4 <!--NeedCopy-->
Note: Drive numbering changes in the shell: SSD 1 reports as drive 0 and SSD 2 as drive 1.
Perform the following steps to restore the RAID array to health by using the atacontrol utility.
1. Detach a failed drive. The failed drive is replaced with a new FRU drive.
2. Attach the FRU drive.
3. Add the FRU drive to the RAID array.
4. Verify that the replacement drive is recognized.
5. Start the rebuild process.
6. Monitor the rebuild process.
7. Verify that the rebuild is successful.
8. Exit the bash shell and verify from the Citrix ADC CLI.
Example when SSD 2 fails
In the following example, SSD 2/drive 1/ata3 has failed.
1. Detach a failed drive.
1 root@ns# atacontrol detach ata3
2 <!--NeedCopy-->
2. Physically, remove SSD 2/drive 1 and replace it with a new FRU drive in slot 2.
3. Attach the FRU drive.
1 root@ns# atacontrol attach ata3
2 <!--NeedCopy-->
4. Add the FRU drive to the RAID array.
© 19992022 Citrix Systems, Inc. All rights reserved. 114

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX 5550 and is the answer not in the manual?

Citrix ADC MPX 5550 Specifications

General IconGeneral
BrandCitrix
ModelADC MPX 5550
CategoryNetwork Hardware
LanguageEnglish

Related product manuals