1 root@ns# atacontrol addspare ar0 ad6
2 <!--NeedCopy-->
5. Verify that the replacement drive is recognized.
1 root@ns# atacontrol status ar0
2 <!--NeedCopy-->
Output:
1 ar0: ATA RAID1 status: DEGRADED
2 subdisks:
3 0 ad4 ONLINE
4 1 ad6 SPARE
5 <!--NeedCopy-->
6. Start the rebuild process.
1 root@ns# atacontrol rebuild ar0
2 <!--NeedCopy-->
7. Monitor the rebuild process.
1 root@ns# atacontrol status ar0
2 <!--NeedCopy-->
Output:
1 ar0: ATA RAID1 status: REBUILDING 10% completed
2 subdisks:
3 0 ad4 ONLINE
4 1 ad6 SPARE
5 <!--NeedCopy-->
Note: Rebuilding the RAID array takes some time.