The BMC reboots to apply the changes. Pings to the BMC succeed aer approximately 60
seconds.
2. Optionally, to configure Ethernet VLAN ID and priority, at the Citrix ADC shell prompt type:
ipmitool lan set 1 vlan id <off|<ID>>
ipmitool lan set 1 vlan priority <priority>
You can either disable or enable the VLAN. Set the VLAN ID to a value from 1 to 4094, and the
VLAN priority to a value from 0 to 7. Aer the network settings have been correctly applied, you
can access the ipmitool remotely from a physically separate machine over the network. For
remote access, enter the BMC user name, BMC password, and the BMC IP address. For example,
to run the ipmitool mc info command, at the shell prompt on a remote machine, type:
ipmitool U <username> P <password> H <bmc IP address> mc info
Obtain health monitoring information
There are two ADC MIBs: the Citrix ADC soware management MIB and the ADC IPMI LOM hardware
management MIB. The soware management MIB is primarily used for monitoring the application
soware and the application sowares utilization of hardware resources, such as CPU % and mem-
ory %. It provides a high level view of the appliance and is therefore suitable for the application mon-
itoring function carried out by an application group within an organization. The LOM MIB is used for
monitoring the hardware health and therefore provides a lower level view of the appliance. It is more
applicable to the network monitoring function carried out by a network monitoring group.
The LOM SNMP traps in the LOM MIB report hardware failures. The ADC SNMP traps in the ADC MIB
report soware failures and hardware load issues.
The ADC MIB has a small subset of hardware sensors. It does not cover any BIOS level failures, because
the BIOS checks the hardware primarily during boot time, before the Citrix ADC soware starts. If the
BIOS detects a failure, it does not load the boot loader. If the boot loader does not load, the operating
system does not load, and therefore the ADC SNMP soware service responsible for sending the traps
does not load.
The Citrix ADC soware Management MIB issues a warning under the following conditions only:
1. If the failure is gradual enough for the main CPU to issue an SNMP alert. An electrical failure
close to the CPU, such as a failed electrical capacitor, occurs too quickly for the CPU to issue an
alert.
2. If the failure happens aer the BIOS, Operating System, and SNMP service have started and nor-
mal boot-up has been successful.
3. If the failure happens while the operating system and other system soware are in a stable
enough state for the SNMP soware service to run.
© 19992022 Citrix Systems, Inc. All rights reserved. 163

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX 5550 and is the answer not in the manual?

Citrix ADC MPX 5550 Specifications

General IconGeneral
BrandCitrix
ModelADC MPX 5550
CategoryNetwork Hardware
LanguageEnglish

Related product manuals