275
INJECTION
SPECIAL FEATURES: FORCED REGENERATION OF THE PARTICLE FILTER
Tools.
Diagnostic stations : LEXIA or PROXIA
Imperative: Respect the safety and cleanliness requirements.
Forced regeneration of the particle filter.
IMPERATIVE: Respect the safety and cleanliness requirements specific to HDi engines.
ESSENTIAL: Connect the vehicle to a gas extractor approved for this type of operation.
In the absence of the required installations, carry out the forced regeneration of the particle filter outside the workshop, in a concreted
area well away from any inflammable materials. Place the vehicle in the high position.
WARNING:
Check that the fuel level is sufficient (at least 20 litres).
Start the engine and allow it to warm up (60°C minimum).
Connect the diagnostic tool to the vehicle’s central socket.
Trigger the regeneration cycle, with the diagnostic tool.
Automatic running of the regeneration cycle of the particle filter:
- Autocheck by the engine ECU.
- Stabilisation of engine speed at 4000 rpm, operating with post injection.
- Change to idling speed (for 30 seconds).
- Stabilisation of engine speed at 3000 rpm, checking of the efficiency of the regeneration of the particle filter.
- Change to idling speed.
NOTE: Let the engine run at idling speed for the benefit of cooling.
Stop the engine.
IMPERATIVE: Wait for at least an hour before any operation on the exhaust line.
ALL TYPES