SM-13235-A
-25-
Condition Causes Measures
Stopvalvebefore/afterthedryeris
closed.
Fullyopenthevalve.
ScreenforY-typestraineratthe
dryerinletisclosed.
Cleanthescreen.
(GX8000)
Treatedflowrateistoolarge. Make1.3orlesstimesofratedflow
Pressure drop before/after the dryer is
toolarge.
Congelationinthedrayer.
・
Ambienttemperatureislow.
・
Inlettemperatureislow.
・
Coolingwinddirectlyblowtothe
dryer.
Preventcongelation.
・
Raisetheambienttemperature.
・
Raisetheinlettemperature.
・
Donotletcoolingwinddirectlyblow
tothedryer.
Powersupplyisturnedoff. Turnonthepowersupply.
All the lamps turn
off, and the dryer
stops.
Powersupplyvoltageisabnormal. Adjustthevoltage.
Safetydeviceison.
・
Ambienttemperatureishigh.
・
Inlettemperatureishigh.
・
Inletpressureislow.
・
Treatedflowrateislarge.
・
Dustfilterisclogged.
・
Fanmotorisbad.
・
Solenoidvalveforliquid
injectionisbad.(GX8000)
Unusualcauseisremovedandreset.
・
Lowertheambienttemperature.
・
Lowertheinlettemperature.
・
Raisetheinlettemperature.
・
Lowerthetreatedflowrate.
・
Cleanthedustfilter.
・
Replacethefanmotor.
・
Replacethevalveforliquidinjection.
(GX8000)
Remotestopwaspushedduring
manualoperation.
Restartthemanualoperation.
Thedryer
suddenlystops.
Only“POWERlamp
ison.
Manualstopwaspushedduringthe
remoteoperation.
Restarttheremoteoperation.