SM-13235-A
>
-5-
3.3Cautionsatoperation
1)
Donotusethedryertoremovehumidityofexceptcompressedair.
Break-down,explosion,orfiremayresult.
2)
Installanearthleakagebreakeratpowersupply.
*Electricshockmayresult.
3)
Groundtoearth.
*Causesofanelectricshockorafire.
4)
Usethedryerwithinspecifications.
*Operationmaystopabnormally,ortheproductʼsservicelifemaybeshortened.
5)
Donotfrequentstartandstopthedryer.
Holdfrequencyofstarting/shuttingoffwithin6times/hour,keepitrunningforatleast5
minutesbeforeshuttingitoffandholdrestartingitfor3minutesorlonger.
*Break-downorshorterservicelifeoftheproductmayresult.
6)
Donotturnonthepowersupplywithoutthepanelon.
*Electricshockorheatinjurymayresult,orrotationpartscouldhurtworkers.
7)
Removedrainbeforeitentersthedryerwhendrainflowsintothedryerwithcompressed
air.
*Draincouldleaktothesecondarysideofthedryer.
8)
Don'tcarryoutreconstructionofthismachine.
*Itbecomesanunexpectedaccidentandthecauseofalifefall.
9)
Donotusethedryerforpneumaticcaissonshieldorrespiratorymedicalequipment.
*Itcouldcauseanaccidentincludesinjury.
10)
Donotusethedryerfortransportationdevicessuchasautomobile,shipetc.
*Vibrationcouldbeacauseofbreakdownoftheinternalcomponents.