5.Functionalexplanation
5.1Functionalexplanation
1)Aircircuit
Thecompressedairwhichbecamewetwarmlyisbeforehandcooledbyprecooler,andthen,it
goesintoanevaporator,heatexchangeiscarriedoutwithcoldfreongas,anditiscooledto
the dew point. Reheat of the compressed air cooled and dehumidified is carried out by
reheater,anditturnsintowarmdryair.
2)Refrigerantcircuit
Itis,andthefreongaswhichbecamehightemperaturehighpressurewiththecompressor
(refrigerant compressor) is cooled and condensed with a condenser, and serves as
high-pressure refrigerant liquid. And by decompressing in a capillary tube, it becomes the
liquidoflow-temperaturelowpressure.Usinganevaporator,bycarryingoutheatexchange
withthewarmdampcompressedair,coolantliquidevaporatesandcoolscompressedairby
theevaporationheat.Thegasifiedrefrigerantreturnstoacompressoragain.
3)Draincircuit
Thesteamincompressedairiscooledandcondensedwithanevaporator,anditisservesas
drain(moisture).Thedraintankiscoveredwithdrain.Thedraincollectedinthedraintankis
discharged periodically when a valve operates, and also the draincookhasclungsothat
dischargemaybemanuallypossible,pleaseuseitamaintenanceorinanemergency.