1.25” Water SpecialiSt ValVe SpecificationS
SPECIFICATIONS
WS1.25 WS1.25CI
Service @ 1 bar/15 psi drop
Backwash @ 1.7 bar/25 psi drop
129 lpm, 7.7 m
3
/h (includes meter and bypass)
121 lpm, 7.3 m
3
/h (includes bypass)
129 lpm, 7.7 m
3
/h (includes meter and bypass)
121 lpm, 7.3 m
3
/h (includes bypass)
Tank Applications:
Softener
Filter (1)
6” - 21” diameter
6” - 24” diameter
6” - 21” diameter
6” - 24” diameter
Inlet/Outlet
Fitting Connections
3/4” - 1.25” Male BSPT
3/4” - 1.5” Sweat
3/4” - 1.5” Solvent
3/4” - 1.25” Male BSPT
3/4” - 1.5” Sweat
3/4” - 1.5” Solvent
Valve Material
Cycles
Regeneration
Noryl (2)
Up to 6
Downow
Noryl (2)
Up to 9
Downow
Operating Pressures
Operating Temperatures
1.4 - 8.6 bar
4° - 43° C
1.4 - 8.6 bar
4° - 43° C
Meter:
Flow Rate Range
Volume Range
(cubic meters)
Totalizer
.95 - 129 lpm
.500 - 250.0m
3
Yes
.95 - 129 lpm
.10 - 2000.0m
3
Yes
Distributor Pilot
32mm O.D. Pipe 32mm O.D. Pipe
Drain Line Connection
3/4” Male NPT Standard
1” Male NPT Optional
3/4” Male NPT Standard
1” Male NPT Optional
Brine Line Connection
3/8” or 1/2” O.D.
Poly Tube Compression
3/8” or 1/2” O.D.
Poly Tube Compression
Mounting Base Options
2-1/2” - 8 NPSM 2-1/2” - 8 NPSM
Height From Top of Tank
187mm 187mm
Shipping Weight w/Meter
2 Kg 2 Kg
Electrical:
Supply Voltage
Supply Frequency
Output Voltage
Output Current
230V AC
50 Hz
12V AC
500 mA
230V AC
50 Hz
12V AC
500 mA
1. Filter tank size calculated @ 407 lpm per m
2
of bed area/10 gpm of backwash per square foot of bed area
2. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company