9-11!
%RG\%UHDNDJH2U&UDFNV)URP*XOOHWV
Probable Cause :
A. Excessive back-up guide "preload".
B. Improper band tension.
C. Guide arms spread to maximum capacity.
D. Improper beam bar alignment.
E. Side guide adjustment is too tight.
F. Excessively worn teeth.
%DQGLV7ZLVWHG,QWR$)LJXUH&RQILJXUDWLRQ
Probable Cause :
A. Excessive band tension.
B. Any of the band conditions which cause the band
to be long (#18) or short (#19) on tooth edge.
C. Cutting a tight radius.
8VHG%DQG,V/RQJ2Q7KH7RRWK(GJH
Probable Cause :
A. Side guides are too tight
rubbing near gullets.
B. Excessive "preload"
band riding heavily against
back-up guides.
C. Worn band wheels causing uneven tension.
D. Excessive feeding rate.
E. Guide arms are spread to maximum capacity.
F. Improper band tracking
back edge rubbing heavy
on wheel flange.
8VHG%DQG,V6KRUW2Q7KH7RRWK(GJH
Probable Cause :
A. Side guides are too tight
rubbing near back edge.
B. Worn band wheels causing uneven tension.
C. Guide arms are spread too far apart.
D. Excessive feeding rate.
MS1318M / MS1318SA