ClimateMaster Geothermal Heat Pump Systems
THW
7
Residential Products Technical Guide
Performance Data - THW010
Source Load
EWT
°F
GPM
WPD
EWT
°F
5.4 GPM
WPD
7.3 GPM
WPD
HC
MBtuh
Power
kW
HE
MBtuh
LWT
°F
COP
HC
MBtuh
Power
kW
HE
MBtuh
LWT
°F
COP
PSI FT PSI FT PSI FT
20 8.3 1.3 3.1
50 32.3 1.10 28.6 61.9 8.6 0.8 1.7 32.7 1.10 32.7 59.4 8.7 1.8 4.0
70 30.0 1.74 27.7 81.1 5.1 0.6 1.4 30.3 1.68 30.3 78.7 5.3 1.1 2.6
90 27.8 2.41 22.9 100.2 3.4 0.5 1.2 28.0 2.35 28.0 98.0 3.5 1.0 2.2
110 25.5 2.99 18.4 119.4 2.5 0.4 0.9 25.7 2.93 25.7 117.4 2.6 0.8 1.9
30
4.2 0.3 0.8
50 31.9 1.10 28.1 61.8 8.5 0.8 1.7 32.1 1.11 32.1 58.8 8.5 1.8 4.0
70 29.6 1.74 23.7 80.9 5.6 0.6 1.4 29.7 1.68 29.7 78.1 5.2 1.1 2.6
90 27.4 2.40 19.2 100.1 3.8 0.5 1.2 27.2 2.34 27.2 97.5 3.4 1.0 2.2
110 25.2 2.97 15.1 119.3 2.8 0.4 0.9 24.8 2.91 24.8 116.8 2.5 0.8 1.9
130 22.8 3.68 10.3 138.4 2.1 0.3 0.7 22.4 3.62 22.4 136.2 1.8 0.7 1.6
8.3 0.9 2.0
50 36.3 1.12 32.5 63.4 9.5 0.8 1.7 36.7 1.12 36.7 60.1 9.6 1.8 4.0
70 33.7 1.76 27.7 82.4 5.6 0.6 1.4 34.1 1.7 34.1 79.3 5.9 1.1 2.6
90 31.2 2.43 22.9 101.5 3.8 0.5 1.2 31.5 2.37 31.5 98.6 3.9 1.0 2.2
110 28.7 3 18.4 120.6 2.8 0.4 0.9 28.9 2.94 28.9 117.9 2.9 0.8 1.9
130 26.0 3.72 13.3 139.6 2.1 0.3 0.7 26.3 3.66 26.3 137.2 2.1 0.7 1.6
50
4.2 0.3 0.7
50 44.2 1.12 40.4 66.3 11.6 0.8 1.7 43.9 1.11 43.9 62.0 11.6 1.8 4.0
70 41.1 1.81 34.9 85.2 7.3 0.6 1.4 40.6 1.71 34.8 81.1 6.9 1.1 2.6
90 38.2 2.53 29.6 104.1 4.8 0.5 1.2 37.5 2.43 29.2 100.3 4.5 1.0 2.2
110 35.1 3.15 24.4 123.0 3.8 0.4 0.9 34.2 3.06 23.8 119.4 3.3 0.8 1.9
130 32.1 3.92 18.7 141.8 2.6 0.3 0.7 31.0 3.82 18.0 138.5 2.4 0.7 1.6
8.3 0.7 1.7
50 48.9 1.13 45.0 68.1 12.7 0.8 1.7 49.3 1.12 49.3 63.5 12.9 1.8 4.0
70 45.5 1.83 39.2 86.8 7.3 0.6 1.4 45.9 1.73 40.0 82.6 7.8 1.1 2.6
90 42.3 2.56 33.5 105.6 4.8 0.5 1.2 42.7 2.46 34.3 101.7 5.1 1.0 2.2
110 38.9 3.18 28.1 124.4 3.8 0.4 0.9 39.3 3.09 28.8 120.8 3.7 0.8 1.9
130 35.5 3.96 22.0 143.1 2.6 0.3 0.7 35.9 3.86 22.7 139.8 2.7 0.7 1.6
70
4.2 0.3 0.7
50 57.0 1.13 53.1 71.1 14.8 0.8 1.7 56.3 1.12 56.3 65.4 14.8 1.8 4.0
70 53.1 1.87 46.7 89.6 8.3 0.6 1.4 52.0 1.73 46.1 84.2 8.8 1.1 2.6
90 49.6 2.63 40.6 108.3 5.5 0.5 1.2 48.1 2.49 39.5 103.2 5.6 1.0 2.2
110 45.8 3.30 34.5 126.9 4.1 0.4 0.9 44.0 3.17 33.2 122.1 4.1 0.8 1.9
130 41.9 4.11 27.9 145.5 3.0 0.3 0.7 39.8 3.98 26.3 140.9 2.9 0.7 1.6
8.3 0.7 1.7
50 61.4 1.14 57.5 72.7 15.8 0.8 1.7 62.0 1.13 62.0 67.0 16.1 1.8 4.0
70 57.2 1.89 50.8 91.1 8.9 0.6 1.4 57.8 1.75 51.8 85.8 9.7 1.1 2.6
90 53.4 2.66 44.3 109.7 5.9 0.5 1.2 53.9 2.52 45.3 104.8 6.3 1.0 2.2
110 49.3 3.34 37.9 128.2 4.3 0.4 0.9 49.8 3.2 38.9 123.6 4.6 0.8 1.9
130 45.1 4.16 30.9 146.7 3.2 0.3 0.7 45.5 4.02 31.8 142.5 3.3 0.7 1.6
THW operating parameters are as follows: Min Source EWT = 20°F; Max Load LWT = 145°F (see application section for design guidelines).
Interpolation is permissible; extrapolation is not.
Operation below 40°F EWT (source) is based upon 15% methanol antifreeze solution.
All performance data is based upon the lower voltage of dual voltage units.
Antifreeze for source water is required for operation in the shaded area and all source EWTs below 40°F.