Water chillers and air/water heat
pumps with centrifugal fans
EN
BRA2 0021÷0061
BRN2 0021÷0061
INSTALLATION, USER AND MAINTENANCE MANUAL

Questions and Answers

  • C
    Candice AdamsAug 15, 2025
    What to do if my CLIMAVENETA BRA2 0021 doesn’t start?
    • R
      Robert AguirreAug 15, 2025
      If your CLIMAVENETA Heat Pump unit doesn't start, first check for a power failure by verifying the voltage and inspecting the safety systems upstream of the appliance. If power is present, the issue might be a faulty contactor coil, HSW15 controller fault, or a faulty start-up capacitor (if featured). In such cases, replace the component. Other potential causes include a faulty compressor or reversed phases (for three-phase units only).
  • H
    Hailey HuberAug 18, 2025
    Why do protection devices trip and shut down the compressor in my CLIMAVENETA Heat Pump?
    • D
      Denise PerezAug 18, 2025
      If the protection devices trip and shut down the compressor in your CLIMAVENETA Heat Pump, check for excessive discharge pressure, low suction pressure, or low voltage. Also, ensure that electrical connections are sufficiently tight. Operation outside permitted limits could also be the cause.
  • M
    Mary BerryAug 22, 2025
    Why CLIMAVENETA BRA2 0021 has insufficient capacity?
    • J
      jordandeborahAug 22, 2025
      If your CLIMAVENETA Heat Pump has insufficient capacity, check for insufficient refrigerant or if the unit is sized too small. Operation outside recommended limits can also cause this issue.
  • D
    Darlene StewartAug 26, 2025
    What causes high discharge pressure in CLIMAVENETA BRA2 0021?
    • D
      dgriffinAug 26, 2025
      If your CLIMAVENETA Heat Pump shows a high discharge pressure (greater than 32 bars), check for high outside water temperature or high utility water inlet temperature.
  • J
    Jason VegaAug 28, 2025
    What causes high suction pressure in CLIMAVENETA BRA2 0021 Heat Pump?
    • H
      Heather MooreAug 28, 2025
      If your CLIMAVENETA Heat Pump has high suction pressure (greater than 20 bars), check for high utility water inlet temperature or a faulty thermostatic expansion valve.
  • U
    uclarkAug 31, 2025
    How to fix a noisy compressor in CLIMAVENETA BRA2 0021?
    • C
      Christopher PhillipsSep 1, 2025
      If the compressor in your CLIMAVENETA Heat Pump is noisy, check for liquid returning to the compressor or inadequate fastening.
  • T
    Tara MorseSep 4, 2025
    What causes low discharge pressure in CLIMAVENETA BRA2 0021 Heat Pump?
    • R
      richard62Sep 4, 2025
      If your CLIMAVENETA Heat Pump has low discharge pressure (less than 16 bars), check for low utility water inlet temperature.
  • A
    Andrea HowardSep 7, 2025
    How to reduce noise and vibrations in CLIMAVENETA BRA2 0021 Heat Pump?
    • M
      Marie ReyesSep 7, 2025
      If you are experiencing noise and vibrations with your CLIMAVENETA Heat Pump, check for contact between metal bodies.
  • P
    Patricia CoxSep 12, 2025
    What to do if CLIMAVENETA BRA2 0021 Heat Pump has loose screws?
    • D
      Dylan Sanders MDSep 12, 2025
      If you find loose screws on your CLIMAVENETA Heat Pump, tighten them.

Summary

Installation, User, and Maintenance Manual

Product Overview

Water chillers and air/water heat pumps with centrifugal fans.

General Warnings and Safety

Essential safety instructions, warnings, and liability waiver.

Unit Identification and Handling

Procedures for identifying, receiving, handling, and positioning the unit.

Product Specifications and Characteristics

Product Description and Components

Details on unit features, components, and identification.

Dimensional Drawings and Hydraulic Connections

Provides dimensions and guidelines for water circuit installation.

System Water Circuit Diagrams

Connection diagrams for BRA2 and BRN2 versions with/without hydronic kit.

System Water Requirements

Information on freezing prevention, glycol solutions, and water quality.

Installation Procedures

Fouling Factors and Connection Sizing

Coefficients for performance adjustment and connection sizes.

Condensate Drain and System Filling;Emptying

Instructions for condensate drain and procedures for filling/emptying the system.

Air Ducting and Outlet Configuration

Characteristics for air ducting and instructions for air outlet position.

Electrical Connections and Power Supply

Electrical Connections Overview and Data

Guidelines and technical data for connecting the unit to the power supply.

Mains Power Supply Connections

Procedure for connecting the main power supply to the unit.

Installer Connections and Accessories

Connecting remote devices, mains power, and optional accessories.

Technical Data and Operating Limits

General Technical Data (BRA2 Models)

Performance specifications for BRA2 models.

General Technical Data (BRN2 Models)

Performance specifications for BRN2 models.

Operating Limits

Graphs showing acceptable operating ranges for cooling and heating.

Performance Curves and Unit Startup

Pressure Drop and Head Information

Graphs for system heat exchanger pressure drop and available pressure head.

Fan Performance Curves

Graphs showing residual static pressure gain versus air flow rate.

Unit Startup and Operation

Procedures for preparing, starting up, activating, and deactivating the unit.

Control Panel Functions

Control Panel Display and LEDs

Explanation of control panel display elements and status LEDs.

Controller Settings: Clock and Scheduler

Procedures for setting clock, date, year, and scheduler time bands.

Controller Settings: Operating Mode and Set Points

Instructions for selecting operating mode and adjusting temperature set points.

Controller Settings: Parameters

Steps to access and modify unit parameters via the control panel.

Alarms and Troubleshooting

Alarm Log Management

Procedure to display and reset the unit's alarm history.

Displaying Alarms

Lists fault codes, their causes, and corresponding solutions.

Peak Limiter Alarm Signals

LED indications and actions for peak limiter alarms.

Troubleshooting Unit Start-Up Issues

Common faults, causes, and solutions for unit start-up problems.

Maintenance Procedures

Shutting Down for Long Periods

Steps for safely deactivating the unit for extended periods.

Routine and Unscheduled Maintenance

Instructions for annual service, chemical washing, and refrigerant.

Troubleshooting Pressure Issues

Causes and solutions for high/low discharge and suction pressure faults.

Disposal

Unit disposal must comply with local legislation.

Useful Information

Technical Assistance and Spare Parts

Contact information for technical support and obtaining spare parts.

CLIMAVENETA BRA2 0021 Specifications

General IconGeneral
BrandCLIMAVENETA
ModelBRA2 0021
CategoryHeat Pump
LanguageEnglish