10.2 Test Run
Test run is described on the installation manual of the
ODU. This is an automatic test run, which will last for
more than 1 hour.
To guarantee the best usage of the unit, you must
regularly check the unit and on-site wiring.
All unit maintenance must be performed by the local
installation companies.
If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard
11 MAINTENANCE AND
SERVICE
Important information for the used refrigerant
10 FINAL CHECK AND TEST
RUN
10.1 Final Check
Before closing the switch of the unit, please read the
following information:
When you complete installation of the unit and have
performed all the necessary settings, ensure that all
the metal plates are closed. This can protect your
from electrical parts and high-temperature parts
inside the unit.
The electric control box cover plate can only be
opened by an electrician who is certified for
maintenance.
Discharge air in the system.
9 DOMESTIC HOT WATER TANK
A domestic hot water tank(with or without booster heater)
can be connected to the unit.
The requirement of the tank is different for different unit
and material of heat exchanger.
Temperature
probe(Ttank)
Coil
Outlet
Inlet
If the tank volume is greater than 240L, the temperature
probe (Ttank) should be installed at a position higher
than half of the tank’s height.
If the tank volume is less than 240L, the temperature
probe should be installed at a position higher than 2/3 of
the tank’s height.
If the booster is installed, the booster heater should be
installed below the temperature probe.
The heat exchanger (coil) should be installed below the
temperature probe.
The pipe length between the hydro module and tank
should be less than 5 meters.
This product has the fluorinated gas, it is forbidden to
release to air.
Refrigerant type: R410A/ Kg or R134a/ Kg
Volume of GWP : 2088 or 1430, tommes CO
2 equivalent
GWP=Golabal Warming Potential
ATTENTION:
Frequency of Refrigerant Leak Checks
1) For equipment tha contains fluorinated greenhouse
gases in quantities of 5 tonnes of CO2 equivalent or
more, but of less than 50 CO
2 equipment, at least every
12 months, or where a leakage detection system is
installed, at least every 24 months.
2) For equipment tha contains fluorinated greenhouse
gases in quantities of 50 tonnes of CO
2 equivalent or
more, but of less than 500 CO
2 equipment, at least every
6 months, or where a leakage detection system is
installed, at least every 12 months.
3) For equipment tha contains fluorinated greenhouse
gases in quantities of 500 tonnes of CO
2 equivalent or
more, at least every 3 months, or where a leakage
detection system is installed, at least every 6 months.
4) This air-conditioning unit is a hermetically sealed
equipment that contains fluorinated geenhouse gases.
5) Only certificated person is allowed to do intallation,
operation and maintenance.
M0WU00002-00