21
SETTING
HOLIDAY AWAY
DHW MODE
DISINFECT
HEAT MODE
FROM
UNTIL
VALUE
on
on
on
on
02-01-2019
16-01-2019
6.4.2 HOLIDAY AWAY
SCROLL
ON/OFF
ON/OFF
OPTIONS
CURRENT STATE
DHW MODE
DISINFECT
HEAT MODE
SCROLL
SCROLL
OFF
ON
ON
ON
HOLIDAY
HOME
HOLIDAY
AWAY
SILENT
MODE
OPTIONS
CURRENT STATE
DHW MODE
DISINFECT
HEAT MODE
OFF
ON
ON
ON
HOLIDAY
HOME
HOLIDAY
AWAY
SILENT
MODE
If holiday away mode is enabled, the icon will be
displayed on the main interface.
The holiday away mode can prevent water from freezing
during holidays and start heating and water heating
before you are back home, thus guaranteeing comfort
and hot water at home.
Go to ''MENU'' > ''OPTIONS'' > ''HOLIDAY AWAY''. Press
''OK''. The following page will appear:
1/2
OPTIONS
FROM
UNTIL
02-01-2019
16-01-2019
HOLIDAY
HOME
HOLIDAY
AWAY
SILENT
MODE
2/2
For example:
Assume that you plan to leave home for a winter
vacation. If the current date is 2018-12-31 and you will
start your holiday two days later, the holiday start date is
2019-01-02. If you have a two-week holiday and you
want to save energy and prevent freezing at home, you
can start holiday away mode as follows:
When DISINFECT is set to ON, and you set the
disinfection mode, the hydro module will automatically
perform disinfection at the set disinfection time prior to
the end of the holiday. For example, if
FROM=2020-01-02, UNTIL=2020-01-16, and
disinfection time is set to 23:00 on Friday, disinfection
begins from 23:00 on 2020-01-10. If you do not set the
disinfection mode, the hydro module will forcedly enter
disinfection mode at 22:00 on the day before the end of
the holiday. If you do not set the disinfection mode, the
hydro module will begin disinfection from 22:00 on
2020-01-16. After the hydro module exits disinfection
mode, the wired controller will send the heat mode
start-up command and DHW mode start-up command to
the hydro module.
TwoutS=TwoutS_H.A_H indicates the heat mode, while
TtankS=TtankS_H.A_DHW indicates the DHW mode.
TwoutS_H.A_H and TtankS_H.A_DHW are set on the
FOR SERVICEMAN interface of the wired controller.
Notes:
In holiday mode, timer and weekly schedule are
invalid until the hydro module exits from holiday
mode.
The CURRENT STATE option determines whether to
enable holiday mode. If CURRENT STATE = OFF,
HOLIDAY AWAY = OFF. If CURRENT STATE = ON,
HOLIDAY AWAY = ON.
The multiple set point is invalid when the hydro
module operates in holiday mode.
If disinfection mode is set in holiday mode, the hydro
module will enter the disinfection mode at 22:00 on
the day before the end of the holiday mode.
In holiday mode, the weather temperature curve is
invalid until the hydro module exits from holiday
mode.
In holiday mode, Preset Temp. is invalid until the
hydro module exits from holiday mode.
If you operate the wired controller in holiday mode, the
following prompt is displayed:
04:27 27-05-2019 sun
OK CONFIRM
NO YES
SCROLL
The ''HOLIDAY AWAY FUNCTION'' is on.
Do you want to turn off the holiday away function ?
M0WU00002-00