Technical data
7 TECHNICAL DATA
Technical features (MONOSplit)
Unit 27M 35M
Refrigerant piping
Liquid line
inch Ø 1/4” Ø 1/4”
mm Ø 6.35 Ø 6.35
Gas line
inch Ø 3/8” Ø 3/8”
mm Ø 9.52 Ø 9.52
Max equivalent length m 25 25
Max. height dierence outdoor unit / indoor unit m ±10 ±10
Refrigerant pre-charge kg/m 0.70 / 5 0.70 / 5
GWP tco 675 675
Tons of equivalent CO tt 0.47 0.47
Additional refrigerant charge g/m 12 12
Unit 27M 35M
Electrical connections
Mains power supply (outdoor unit)
V / Hz / p 230 / 50 / 1
n° cables / cross section 2 x 1.5mm
2
+ G
Outdoor unit --> indoor
unit connection
Signal n° cables / cross section 2 x 1.5mm
2
2 x 1.5mm
2
Power supply n° cables / cross section
2 x 1.5mm
2
+ G 2 x 1.5mm
2
+ G
Power consumption (outdoor unit + indoor unit) 27M 35M
Rated power input
Cooling Nominal (Min~Max) W 600 (100~1.260) 900 (130~1.650)
Heating Nominal (Min~Max) W 623 (110~1.320) 950 (120~1.500)
Rated current input
Cooling Nominal (Min~Max) A 2.6 (0.4~5.5) 3.91 (0.6~7.2)
Heating Nominal (Min~Max) A 2.7 (0.4~5.7) 4.13 (0.5~6.5)
NOTE:
– at max. pipe length, the yield is approximately 90%
– with a height dierence >5m it is advisable to insert a siphon.