7 - REGULATION
UNIT PARAMETER tab 1
2 CompAmb Enables Tambient comp. 0=No 1=Cool 2=Heat 3=Always
3 ENCCar Enables load compensation 0=No 1=Cool 2=Heat 3=Always
4 CompExt Enables Toutside comp. 0=No 1=Cool 2=Heat 3=Always
5 WaterReset Enables Water Reset 0=No 1=Cool 2=Heat 3=Always
6 CompDutyEn Enables Duty compensation 0=No 1=Cool 2=Heat 3=Always
7 DemandLimitEn Demand Limit enabling 0=None 1=priority of aux. release 2=priority of compressor release 3 =
Current measure
8 CompONEN Enables Duration comp. 0=No 1=Cool 2=Heat 3=Always
12 EnH2OSanitaria Enabling of DHW management 0=No DHW, 1=DHW and system without restrictions, 2=DHW and
system heat only, 3=DHW and system cool only, 4=DHW only mode
13 CaldaiaEn Enables boiler function + Heat pump 0=No/1=Always2=disabled in DHW
16 EnUrExt Enables ext. RH% probe 1=Yes/0=No
17 EnDTIncongruent
e
Enables inconsistent DeltaT for units reversal on the refrigerant circuit 1=Yes/0=No
18 EnPaux Enabling of the aux. heater 0=No/1=Always2=disabled in DHW
19 ControlMode Enables the temperature automatic control
20 PumpBord Presence of second pump 0=Customer management 1=Single pump on the unit 2=Single
pump+reserve 3=Pump at variable flow-rate
24 ControlPump Enables off control of the utility pump: 0=No 1=according to the ambient set 2=according to the storage
temperature
25 RemOnOffMode Configure DI inputs 1=On/Off, 0=thermal request from the ambient
62 MaxCAmbC Max. correction value for ambient temperature,Summer
63 DeltaCambC Band of ambient setpoint for Ambient Temp. correction. Summer
64 MaxCAmbH Max. correction value for ambient temperature,Winter
65 DeltaCambH Band of ambient setpoint for Ambient Temp. correction. Winter
66 PesoCorTamb Weight of the ambient temperature correction
82 CompCarC Max. Summer charge compensation
83 CompCarH Max. Winter charge compensation
84 MediaDelta Time for the average on (Ting. - Tout)
85 MinDeltaC Summer temperature min. delta
86 MaxDeltaC Summer temperature max. delta
87 MinDeltaH Winter temperature min. delta
88 MaxDeltaH Winter temperature max. delta
104 CextMaxC Out. Temp. of Summer max. correction
105 CextMinC Out. Temp. of Summer min. correction
106 CextMaxH Out. Temp. of Winter max. correction
107 CextMinH Out. Temp. of Winter min. correction
108 MaxCExtC Summer max. correction value
109 MaxCExtH Winter max. correction value
110 HExtMinC Min. correction ext. enthalpy
111 HExtMaxC Max. correction ext. enthalpy
127 MaxCWRH Max. value of the Winter WR correction
128 SWRMAXH Signal of Winter max. correction
129 SWRMinH Signal of Winter min. correction
ID
Description Extended description

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CLIVET WSAR-MT-E and is the answer not in the manual?

CLIVET WSAR-MT-E Specifications

General IconGeneral
BrandCLIVET
ModelWSAR-MT-E
CategoryHeat Pump
LanguageEnglish

Related product manuals