Inspections
In case of
negative outcome
Resolution
by
Check the absence of slits,
cracks, points of rust on the
structure of the MEWP.
It is strictly
forbidden to use the
MEWP. Contact he
Technical Assis-
tance Service.
CMC
Check that the safety devices
(emergency stop buttons, stabi-
lizers-boom interlock System) are
working perfectly.
It is strictly
forbidden to use the
MEWP. Contact he
Technical Assis-
tance Service.
CMC
Check that the controls and the
warning lights are working per-
fectly.
It is strictly
forbidden to use the
MEWP. Contact he
Technical Assis-
tance Service.
CMC
Check the integrity of the tube
holder chains.
It is strictly
forbidden to use the
MEWP. Contact he
Technical Assis-
tance Service.
CMC
Check that the locking systems
of the pins (pins, rings etc.) are in
perfect conditions of conservation
and efficiency.
It is strictly
forbidden to use the
MEWP. Contact he
Technical Assis-
tance Service.
CMC
Inspections
In case of
negative outcome
Resolution
by
Check the integrity of the hos-
es, unions, and of the compo-
nents of the hydraulic system:
make sure that there are no oil
leaks in the hydraulic system.
Replacement
USER/
CMC
Check that there are no loose
Restoration of the
connections
USER/
CMC
Check that there are no signs of
collision on the equipment.
It is strictly
forbidden to use the
MEWP. Contact he
Technical Assistance
Service.
CMC
8.2
Weekly maintenance
(or every 40 hours)
Check the absence of slits, cracks, points of rust
on the structure of the MEWP frame (use torches or
lamps to inspect the internal part under the floor).
USER / CMC
Check the cleanliness condition of the air filter in
the ruck and in the auxiliary motor
.
USER / CMC
Check the cleanliness of the
8.3
Monthly maintenance
(or every 120 hours)
USER / CMC
Check the tightening of the slewing ring, gear mo-