Chapter 3: Service & maintenance
Alerts in the Bridge Alert Management (BAM) system 61
3333
2. If it is a DSC related warning, select Silent at the DSC popup. This will
acknowledge the BAM alert in the list.
3. If it is a non-DSC warning alert, select ACK to acknowledge the alert.
The alert icon changes into the acknowledged version and stops
flashing.
4. Caution alerts do not need to be acknowledged. When they are rectified
they automatically disappear from the list.
5. Move back and forth in the list with the arrow soft key or . The
text at the top shows the number in the list and the total number of
alerts in the list (1/3 in the example above: This is the highest priority
alert in the list (1) and there are 3 active alerts in the list).
List of BAM alerts
The list below shows the alerts that may appear in the display.
Responsibility transfer: The SAILOR 6300 MF/HF DSC accepts
responsibility transfer requests for all category B Warnings.
Escalation time: All Warnings are escalated as Warning after 4 minutes.
This is not a DSC acknowledgement - it is strictly an
acknowledgement of the related BAM alert.
ID/In-
stance
Prio-
rity
Cate-
gory
Title Description Reasons and remedy
3022/1 W B AC Power
Outage
AC power
outage has
occurred.
Check AC power distribution.
3022/2 W B AC_ALR
TU
AC power
outage has
occurred.
No AC power to the Transceiver
Unit. Check AC power distribution.