Chapter 3: Service & maintenance
62 Alerts in the Bridge Alert Management (BAM) system
3023/1 C B PS
COMM
Lost
Power supply
communicati
on lost.
Check LAN-cable to SAILOR 6081
Power Supply Unit and Charger.
No communication with the
power supply.
3023/2 C B BATT
VOLT
Low
Battery and
charger.
Voltage
below limit.
The battery voltage is below the
limit.configured for the SAILOR
6081 Power Supply Unit and
Charger.
3023/3 C B BATT
VOLT
High
Battery and
charger.
Voltage
above limit.
The battery voltage is above the
limit.configured for the SAILOR
6081 Power Supply Unit and
Charger.
3023/4 C B Supply
VOLT
Low
Supply
voltage too
low.
The supply voltage is too low for
the SAILOR 6300 MF/HF DSC
.
Check the power supply and
make sure the power supply
matches the input voltage
specifications stated in the
installation manual for th
e
SAILOR 6300 MF/HF DSC. .
3023/5 C B Supply
VOLT
High
Supply
voltage too
high.
The supply voltage is too high for
the SAILOR 6300 MF/HF DSC
.
Check the power supply and
make sure the power supply
matches the input voltage
specifications stated in the
installation manual for th
e
SAILOR 6300 MF/HF DSC.
3078/1 W B Printer
Status
No
connection
to printer.
Check the printer. Printer is not
connected.
ID/In-
stance
Prio-
rity
Cate-
gory
Title Description Reasons and remedy