7.3.1 1 – All parts of the printhead
After all operation involving fresh concrete (not for dry-runs etc.).
Thoroughly clean using high pressure water or similar:
• Material hopper (inside and outside): Use the excess valve located on bottom.
• Extruder pump: run clean water through pump until outlet water is clean.
• Nozzle and Nozzle clamp: Dismount and clean separately.
• Extruder outlet: Spray from underneath while pump is running.
• Mixing shaft: Take out mixing shaft and clean separately.
7.3.2 2 – Material hose
After all operation involving fresh concrete (not for dry-runs etc.).
Thoroughly clean material hose, using specified foam balls and high-pressure water outlet on m-tec pump
(see m-tec manual)
7.3.3 3 – Mixer pump
Thoroughly clean mixer and pump unit following m-tec manual.