EasyManua.ls Logo

Coca-Cola Freestyle 7000 - Flush the Sanitizer

Coca-Cola Freestyle 7000
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7: Water Circuit Cleaning
Classified Confidential Page 44 of 46
VI. Flush the Sanitizer
Flush Sanitizer from the water circuits and carbonation tank.
Step
Action
1.
From the Technician UI, select CARB WATER until nothing flows from the nozzle.
2.
From the Technician UI, select PLAIN WATER until nothing flows from the nozzle.
3.
Disconnect the Water CIP Tubing Kit from the Dispenser Electric Pump.
4.
Reconnect the dispenser incoming water line to the inlet of the Dispenser Electric Pump.
5.
In the backroom, open the water supply to the dispenser.
6.
From the Technician UI, select CARB WATER and flow for a minimum of three minutes.
This allows supply water to flush the sanitizing solution from the Carb Water circuit.
This may require multiple separate presses due to timeout.
7.
In the backroom, open the CO2 Shutoff valve.
8.
From the Technician UI, select CARB WATER and flow until only CO2 blows from the
nozzle. This may require multiple separate presses due to timeout.
9.
From the Technician UI, select PLAIN WATER and flow for a minimum of one minute.
This allow supply water to flush the sanitizing solution from the Plain Water circuit. This
may require multiple separate presses due to timeout.

Other manuals for Coca-Cola Freestyle 7000

Related product manuals