Do you have a question about the Cocoon CWS 4000 and is the answer not in the manual?
Describes how to position the CWS4000 unit for optimal use, including floor, bed, and IV pole mounting.
Instructions for initial setup: connecting power, preparing the warming blanket, and connecting the air hose.
Steps for selecting temperature settings, operating the unit, and understanding its automatic functions and alarms.
Explains the meaning of various symbols used on the CWS4000 device and its documentation.
Highlights critical hazards like explosive environments and electrical shock risks.
Emphasizes precautions regarding qualified personnel, electrical safety inspections, fluid contact, and proper usage.
Details operational cautions related to voltage range, mounting height, specific temperature settings, and filter life.
Discusses compliance with EMC standards and potential interference issues with other equipment.
Procedure for cleaning the unit's exterior, control panel, and air inlet slots.
Recommends regular electrical safety inspections and references Australian technical standards.
Details annual inspection steps to verify CWS4000 functions, including temperature control verification.
Optional procedure to test the over-temperature limit function using a PC and serial cable.
Guides on replacing the HEPA filter based on operating hours or time, and resetting the filter indicator.
Troubleshooting steps for when the warming blanket fails to inflate, checking connections, kinks, and filter.
Explains why the standby indicator might not light, relating it to temperature limit thermostats and fuse checks.
Specifies that repairs should only be performed by qualified personnel.
Describes the functions and components of the CWS4000 Control Board, including the microcontroller and its functions.
Details the functions of the Sensor Board, including the digital temperature sensor and limit thermostats.
Explains the general electrical connectivity between the CWS4000's subassemblies.
Provides a component legend for the Control Board, identifying parts and their locations.
Provides a component legend for the Sensor Board, listing its parts.
Detailed schematic diagram for the CWS4000 Control Board.
Schematic diagram for the CWS4000 Sensor Board.
Block diagram illustrating the system's connectivity and major components.
Lists the main components and parts included in the general assembly of the CWS4000.
Detailed parts list for the CWS4000 Control Board.
Detailed parts list for the CWS4000 Sensor Board.
| Category | Medical Equipment |
|---|---|
| Power Source | Rechargeable Lithium-ion battery |
| Operating Temperature | 10°C to 40°C |
| IP Rating | IP22 |
| Compatibility | Standard wound care solutions |
| Storage Temperature | -20°C to 50°C |
Loading...