FILTERBREW & SERVING CONCEPT
11
PROGRAMMING
Cater
Adjusting of water quantity
Adjusting of brewing time
ADJUST DISPLAY
25% 5
20% 4
15% 3
10% 2
5% 1
0% 0
-5% -1
-10% -2
-15% -3
-20% -4
-25% -5
The procedure to enter this mode is the following:
Press buttons and at the same time for 5 seconds until
you hear 3 beeps.
The display shows the current setting.
Adjust with the buttons = (increase) and = (decrease).
Presse the button to save new settings and return to normal
mode.
In this mode the time for the brewing done buzzer activation can be
adjusted. The procedure to enter this mode is the following:
Press buttons and at the same time for 5
seconds until you hear 5 beeps.
The display shows the current setting.
Adjust with the buttons = (increase) and = (decrease).
Presse the button to save new settings and return to
normal mode.
The brewing time is the same regardless adjustment of the outlet valve time.