FILTERBREW & SERVING CONCEPT
14
PROGRAMMING
ADJUST DISPLAY
+5°C
5
+4°C 4
+3°C 3
+2°C 2
+1°C 1
0 0
-1°C -1
-2°C -2
-3°C -3
-4°C -4
-5°C -5
To w e r
Normal operation with reduced outlet time
Adjusting of temperature sensor
In this mode a temperature offset for the NTC sensor can be adjusted.
The procedure to enter this mode is the following:
Press buttons , and at the same time for 5
seconds until you hear 2 beeps.
The display shows the current setting.
Adjust with the buttons = (increase) and = (decrease).
Pressing the button to save new settings and return to normal
mode.
This mode is entered by pressing and before turning the mains
switch on. The buzzer gives a 5s beep to indicate this mode.
This machine operates like in normal mode but the outlet times are reduced by 90% in order to allow
faster adjustment of valve times.
Select machine type
In this mode the machine type can be chosen. The procedure to enter this mode is the following:
Press buttons , and at the same time before turningthe mains switch on until
y
ou hear 6 beeps.
The display shows the machine type.
Step up with button and step down with button .
Presse the button to save new setting and return to normal mode.
MACHINE TYPE DISPLAY
OUTLET TIME (s)
BUZZER TIME(s)
HALF
FULL
10L T1 300 600 300
5L T2 150 300 300