Operation Manual P750/P1500/P3000
Cold Jet, LLC Page 27
A reduction of more than 20 psig (1.4 bar) in the supply line, indicated at the CO
2
injection pressure gauge.
Excessive gas in the liquid supply line (erratic chamber pressure gauge).
Within the machine itself, the following items can affect production:
Dirty exhaust collector screens.
Clogged liquid CO
2
filters.
CO
2
Snow behind the Piston
There are two reasons for snow accumulating behind the piston:
The wear rings are worn and snow is being pushed past them during each cycle.
The injector ball valve is not shutting off completely, allowing snow to build up behind
the piston as it advances. The chamber pressure gauge will spike high and then drop to
zero. Too much buildup will cause the unit to shut off the extrusion process and a Long
Retract Time fault will display.
Specifications
P1500
P3000
Dimensions
59 x 74 x 49 in.
(150 x 74 x 124 cm)
73 x 76 x 71 in.
(192 x 211 x 180 cm)
Weight
3765 lb (1708 kg)
6825 lb (3100 kg)
Pellet Capacity
1200 lb/hour (545.5 kg/hour)
2400 lb/hour (1091 kg/hour)
Power Requirements
200-480 Volt AC
3-Phase, 20 HP, 16 kw
200-480 Volt AC
3-Phase, 20 HP, 16 kw