EasyManua.ls Logo

Cold Jet P1500 - Start-Up Procedure; Shut Down Procedure

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual P750/P1500/P3000
Cold Jet, LLC Page 8
Start-Up
1. Open the liquid CO
2
supply and vapor CO
2
supply valves.
2. Turn the Main Power switch [1] to the ON positon.
3. Verify the E-Stop button [3] is not depressed.
4. Turn the Chamber Power switches [2] to the OFF (O) position.
5. Press the Reset button [4].
6. Turn the Chamber Power switches [2] to the ON (I) position.
Shut Down
1. Turn the Chamber Power switches [2] to the OFF (O) position.
2. Turn the Main Power switch [1] to the OFF positon.
3. Close the liquid CO
2
and vapor CO
2
supply valves.

Related product manuals