14
Treadmill Hardware Manual 1011-0002 v1.02
Teflon tape or Teflon pipe sealant
15mm (9/16in) Open-End Wrench or Adjustable Crescent Wrench
WARNING!!! Place the protective caps over the open ports of air-fittings when not in use.
To setup the Air-Puff Stimulus, do the following:
Place the Air Reservoir near the treadmill, but out of the way
Remove and save the protective caps from the air fittings on the rear of the treadmill and the Air
Reservoir.
Place a mark 2.54cm (1in) from the end of the 2.4m (8ft) air-supply line. Then fully insert the 2.4m (8ft)
tube into the air fitting on the rear of the treadmill. The mark should be flush with the end of the
fitting.
Place a mark 2.54cm (1in) from the free end of the 2.4m (8ft) air-supply line. Then fully insert the 2.4m
(8ft) tube into the air fitting on the air reservoir. The mark should be flush with the end of the fitting.
Place a mark on the free end of the 6m (20ft) air-supply line 19mm (¾in) from the end. Then, fully
insert the 6m (20ft) tube into the fitting on the reservoir brass tee. The mark should be flush with the
end of the fitting.