EasyManua.ls Logo

Columbus Instruments Exer 3/6 - User Manual

Default Icon
127 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Serial Number:__________________
(Please refer to this number for service)
Exer 3/6 Treadmill,
Treadmill Controller
and Treadmill Software
Instruction Manual
0257-904L, 06/24/2016
Copyright Columbus Instruments 2016
Columbus Instruments
Columbus InstrumentsColumbus Instruments
Columbus Instruments
E-mail: sales@colinst.com
http://www.colinst.com
Columbus, Ohio 43204-2121 U.S.A.
950 North Hague Avenue
Fax: (614) 276-0529
Phone: (614) 276-0861

Table of Contents

Other manuals for Columbus Instruments Exer 3/6

Questions and Answers

  • R
    Richard ParkerAug 14, 2025
    What to do if Columbus Instruments Treadmill belt does not turn?
    • T
      Tammy MillerAug 14, 2025
      If the treadmill belt isn't turning, there are several things you can check. First, make sure the belt speed is set to 06.0 M/M or higher. Ensure that the 'RUN/STOP' switch is in the 'RUN' position and that the motor cable is securely connected. If the belt is jammed to one side of the drive shaft, adjust the belt tension and manually turn the belt to loosen it.
  • R
    Rebekah Martinez DVMAug 17, 2025
    Why is my Columbus Instruments Exer 3/6 Treadmill exercise belt pulling to one side?
    • T
      Todd WebbAug 17, 2025
      If the exercise belt is pulling to one side of the drive shaft, the belt tension is likely unequal. Readjust the belt tension to correct this issue.
  • C
    Cesar HolmesAug 21, 2025
    How to troubleshoot Columbus Instruments Treadmill if power indicator light does not turn on?
    • S
      Sarah HarrisonAug 21, 2025
      If the power indicator light doesn't turn on, check for a blown fuse, verify proper voltage at the AC receptacle, and replace any bad power cords.
  • R
    regina04Aug 25, 2025
    What to do if the LCD of my Columbus Instruments Exer 3/6 Treadmill Controller is not working?
    • M
      Michael MartinezAug 25, 2025
      If the LCD of your Columbus Instruments Treadmill Controller is not lit continuously or doesn't display text, ensure the contrast knob is adjusted fully clockwise. If the issue persists, it may indicate a fault within the Treadmill Controller.
  • A
    Antonio MartinezAug 28, 2025
    How to check the AC power cord on a Columbus Instruments Exer 3/6 Treadmill?
    • A
      Anne PenaAug 28, 2025
      Make sure the AC power cord of your Columbus Instruments Treadmill is fully inserted into both the Treadmill Controller and the AC power outlet.
  • A
    Alan Stewart PhDAug 30, 2025
    How do I check the serial cable connection on my Columbus Instruments Exer 3/6 Treadmill?
    • B
      Brenda SchmidtAug 30, 2025
      To check the serial cable between your host computer and the Columbus Instruments Treadmill's Computer Interface, ensure it's properly connected. When the computer sends information to the CI-Bus, the transmit indicator (top left yellow LED on the “CONTROLLER” port of the Computer Interface) should flash briefly.
  • K
    Kim BakerSep 3, 2025
    How to check the power supply for the Columbus Instruments Treadmill Computer Interface?
    • R
      Rebecca GibsonSep 3, 2025
      Verify that the power plug is correctly installed in the Computer Interface and that the power supply is properly inserted into the AC power outlet for your Columbus Instruments Treadmill.
  • T
    Tiffany RiddleSep 7, 2025
    How to check the RJ-45 cable on a Columbus Instruments Exer 3/6?
    • N
      Nicole YoderSep 7, 2025
      Ensure the RJ-45 cable between the Computer Interface and the Treadmill Controller of your Columbus Instruments Treadmill is fully inserted, with the connector locking tab snapped into the jack.
  • S
    Spencer HawkinsSep 10, 2025
    How to check the power indicator on the Columbus Instruments Treadmill Computer Interface?
    • C
      Christopher RichmondSep 10, 2025
      Ensure that the top right green LED on the “CONTROLLER” port of the Computer Interface is continuously lit on your Columbus Instruments Treadmill.

Summary

SECTION 1 INTRODUCTION

1.0 System Overview

Provides an overview of the Exer 3/6 Treadmill's design, capabilities, and components.

SECTION 2 COMPUTER SETUP

2.0 Treadmill Software Installation

Step-by-step guide for installing the Treadmill Software from CD-ROM.

2.1 CI-Bus Hub Driver Installation

Instructions for manually installing the CI-Bus Hub USB communication drivers.

SECTION 3 HARDWARE SETUP

3.1 Assembling the Exer 3;6 Treadmill

Provides instructions for assembling the main treadmill unit.

3.2 Downhill Running Adapter

Instructions for assembling and attaching the Downhill Running Adapter.

3.3 Assembling the Air-Puff Stimulus

Details the items and steps for assembling the Air-Puff Stimulus system.

3.4 Connecting the Components

Guide for connecting the CI-Bus Hub, network cable, and treadmill controller.

SECTION 4 STAND-ALONE GENERAL EXERCISING WITHOUT THE PC

4.0 Stand-Alone Initialization

Procedure to initialize the controller for standalone operation, preventing unwanted startup.

4.1 User Menu Settings

Accessing and navigating the controller's user menu for settings and calibration.

4.2 Loading the Subjects

Steps for loading animals onto the treadmill and setting up shock stimulus.

SECTION 5 PERFORMING A PC-CONTROLLED EXPERIMENT

5.0 Treadmill Controller Setup

Procedure to set up the Treadmill Controller for PC-controlled experiments.

5.1 Treadmill Shock Detection Setup

Instructions for setting up the Treadmill Shock Detection unit.

5.2 Incline Controller Setup

Guide for setting up the Incline Controller for operation.

5.3 Treadmill Software Initialization

Steps to launch and initialize the Treadmill Software on the host computer.

5.4 Manual Experiment

Guide to setting up and running a single-speed or acceleration experiment.

5.4.3 Start Manual Experiment

Procedure to start a manual experiment and load animals.

5.5 Profile Mode Experiment

Overview of running experiments with dynamic speed, acceleration, and incline profiles.

5.5.1 Creating a Profile

Steps to define experiment periods with speed, duration, incline, and shock.

5.5.2 Start Profile Mode Experiment

Procedure to start a profile mode experiment and load animals.

SECTION 6 TREADMILL USER MENU

6.6 AutoCal Speed

Performs automatic belt speed and odometer distance calibration.

SECTION 4 SOFTWARE SETUP

4.1 Treadmill Software Initialization

Starts and initializes the Treadmill Software, scanning for devices.

SECTION 5 TROUBLESHOOTING

5.1 Hardware

Tips for identifying and resolving hardware-related issues.

Columbus Instruments Exer 3/6 Specifications

General IconGeneral
Running Surface18 x 48 in (46 x 122 cm)
Speed0.5 - 15 mph (0.8 - 24 kmph)
Elevation0 - 25%
User Weight Capacity400 lbs (181 kg)
Speed Range0.5 - 15 mph (0.8 - 24 kmph)
Incline Range0 - 25%
Belt Size18 x 48 in (46 x 122 cm)
ControlComputer Interface
Data OutputRS232
Shock GridOptional
Stimulus GridOptional