65
7.2.0 Adding Devices to the CI-Bus
Use the following procedure to add new devices to the CI-Bus:
Note the addresses of the currently configured and detected devices on the CI-Bus. Typical addresses
are: 220, 230 and 235 for the Treadmill Controller, Treadmill Shock Detection unit and the Incline
Controller respectively.
Check the addresses of the devices you intend to add to the CI-Bus. Typically, it is printed on the
serial tag or may be available to view or edit electronically by the device itself. Each address should
be unique and different from all others on the CI-Bus, inclusive of all ports on the CI-Bus Hub.
Remove the orange terminator from the last device on the end of the CI-Bus.
Connect the new devices by way of CAT5 Network cables.
Install the orange terminator in the available “CI-Bus” port of the last device.
Switch “On” the power to all devices.
Click the Scan for New Devices button and program will discover all devices on the CI-Bus.
If all devices are properly detected, click the Exit button. A “Configuration” window will open.
Click Yes to save the changes and return to the main window.
7.2.1 Removing Devices from the CI-Bus
Use the following procedure to remove existing devices from the CI-Bus:
Switch “Off” the AC power of the devices to remove.
Click the Scan for New Devices button and program will discover all devices on the CI-Bus.
If all of the expected devices are properly detected, click the Exit button. A “Configuration” window
will open.
Click Yes to save the changes and return to the main window.