6.0 Restore Defaults
The top option on the list. This is used to restore all of the factory settings saved during it’s calibration
performed at Columbus Instruments. This may be necessary during service as to restore a known
configuration should for any reason the current settings are unknown or have become corrupt and the
Treadmill Controller is non-responsive.
Press the “ODOMETER RESET” button to select the option. “Are you sure?” will be displayed.
Then press-and-hold the “ODOMETER RESET” button to restore the factory settings. Else, press-
and-release to cancel.
6.1 Serial Number
This is used to see the electronic serial number which should match the Columbus Instruments serial tag on
the outside of the unit. For service, this number may be referenced to lookup any specific details or notes
about your particular Treadmill and Controller. This option is non-editable. It is provided for reference
and additional information.
6.2 Run-Time Meter
This is used to report the total amount of time the Treadmill Controller has been powered-on. The format
is Days : Hours : Minutes (DHM). To preserve the integrity of the EEPROM (non-volitile storage), the
Run-Time Meter is saved every ten minutes. This option is non-editable. It is provided for reference and
additional information.
6.3 Run-Time Odometer
This is used to report the total accumlated distance (in meters) the treadmill belt has moved. This distance
is formated for eaisier viewing. To preserve the integrity of the EEPROM (non-volitile storage), the
Odometer is saved every ten minutes. This option is non-editable. It is provided for reference and
additional information.
6.4 Unit ID
This is used to set the CI-Bus address of the Treadmill Controller. The address should be properly set from
the factory, however, this option allows changes as needed. The Unit ID should be unique and not match
the address of another device with which it is connected on the same bus. The Unit ID ranges from 1 to
254 (220 typical).
Press the “ODOMETER RESET” button to select the option. The displayed address is now editable.
Use the “SPEED” knob to select the new value for the Unit ID.
Then press-and-hold the “ODOMETER RESET” button to save the new setting. Else, press-and-
release to cancel.

Table of Contents

Other manuals for Columbus Instruments Exer 3/6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Columbus Instruments Exer 3/6 and is the answer not in the manual?

Columbus Instruments Exer 3/6 Specifications

General IconGeneral
BrandColumbus Instruments
ModelExer 3/6
CategoryTreadmill
LanguageEnglish