Reference Guide
InteliMains
NT
®
Bus Tie Breaker Application
IM-NT-BB, IM-NTC-BB, IM-NT
SW version 3.0, May 2013
Copyright ©2013 ComAp a.s.
ComAp a.s.
Kundratka 17, 180 00 Praha 8, Czech Republic
Tel: +420 246 012 111, Fax: +420 266 316 647

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ComAp IM-NT-BB and is the answer not in the manual?

ComAp IM-NT-BB Specifications

General IconGeneral
ModelIM-NT-BB
TypeController
Communication InterfacesRS485
Operating Temperature-40°C to +70°C
InputsDigital, Analog
OutputsRelay, Digital

Summary

System Overview

Configurability and Monitoring

Details the adaptability of the controller and available PC/mobile tools for configuration.

Installation

IM-NT Installation Instructions

Provides installation steps specifically for the InteliMains-NT-GC controller with a built-in display.

IM-NT-BB and IM-NTC-BB Installation Instructions

Details installation procedures for BaseBox controller versions without a built-in display.

Voltage and Current Inputs

Explains wiring for voltage and current measurements, including safety warnings.

Putting It Into Operation

Connection to a Controller Using PC

Explains various methods to connect a PC to the controller for monitoring and configuration.

Modification of Configuration, Setpoints Etc.

Guides on how to modify controller settings and configuration using PC tools.

Programming of a Controller

Details the process for standard and non-responsive controller programming.

Password Management

Covers user administration, access group settings, and password break protection.

Function Description

Power Management

Covers standard power management setpoints and crucial roles in Control Group functions.

Load Shedding

Describes the function for automatically disconnecting and reconnecting loads.

Remote Alarm Messaging

Explains how to configure up to five channels for Active Call, Email, and SMS.

Controller Redundancy

Discusses redundant systems using binary signals and CAN bus for failover.

Force Value – Step by Step Guide

Provides a guide on how to use the Force value function for temporary setpoint changes.

Modbus Reading and Writing

Describes controller support for Modbus Slave functions for reading/writing objects.

Protections and Alarm Management

Protection Groups

Details configurable and fixed protection groups and their setpoint groups.

Protection Types

Lists and describes various protection types, their actions, records, and reset needs.

Default Protections in MCB/MGCB Applications

Details firmware-based default protections for Bus Left and Bus Right.

Bus Left Voltage and Frequency Protections - Limits and Indications

Explains limits and indications for BusL voltage and frequency protections.

Bus Right Voltage and Frequency Protections - Limits and Indications

Explains limits and indications for BusR voltage and frequency protections.

User Configurable Protections

Describes user-configurable protections and provides a guide for configuration.

Circuit Breakers Operation Sequence, MGCB/MCB Fail Detection

List of Objects

Setpoints

Table of Setpoints

Provides a detailed list of all setpoints, categorized by group.

Values

Binary Input Functions

Table of Binary Input Functions

Lists and describes all available binary input functions and their related FW.

Binary Output Functions

Table of Binary Output Functions

Lists and describes all available binary output functions.

Analog Input Functions

Table of Analog Input Functions

Lists and describes available analog input functions.