32
Configuring via PC
Errors and indications
INDICATION SOLUTION
RED LED LIT STEADILY
+
DETERRENT TONE
Line short-circuit Check connections
Dual power supply present
Remove jumper J4 on the audio/video
module
Button modules with the same ID Check the button module IDs
Programming selector positioning error
Check the position of selectors S1 and
S2 (they cannot both be set to ON)
RED LED FLASHING
Device in programming
All device configurations can be implemented via PC and ViP Manager configuration software, which is available to download
free of charge from the website pro.comelitgroup.com
(See programming manual)
.
For example:
• programming the user codes associated with the buttons
• activating audiovisual indications
• adjusting the backlighting and twilight sensor threshold
• setting the functions that can be assigned to the RTE input (lock-release, relay control, actuator control, etc.)
• setting activations that can be assigned to the module SE outputs and relay
3 You will need a USB micro-USB cable.