Configuration CCT 800 Industrial Stations EE 8000
34 3.1/0614
Recommended Settings from praxis tests:
Simplex:
Duplex:
Open Duplex:
Loudspeaker Settings Background noise
internal
loudspeaker max. 9
approx. 100 dBA
1
microphone - 15 dB
1
maximal speaker distance to the device: 2 to 3 cm (0.79in to 1.18in)
Loudspeaker Settings Background noise High volume duplex mode
internal
loudspeaker max. 4
none
1
inactive
microphone 0 dB
internal
loudspeaker max. 8
none
2
active
microphone -15 dB
internal
loudspeaker max. 8
up to 95 dBA
2
inactive
microphone -15 dB
1
speaker distance to the device: up to 3 m (9.8ft)
2
maximal speaker distance to the device: 2 to 3 cm (0.79in to 1.18in)
Loudspeaker Settings Background noise
internal
loudspeaker max. 3
none
1
microphone - 12 dB
external sound projector
3
loudspeaker max. 7
none
1
microphone -9 dB
external sound projector
3
loudspeaker max. 8
up to 90 dBA
2
microphone -12 dB
external pressure
chamber loudspeaker
3,4
loudspeaker max. 8
up to 95 dBA
2
microphone -15 dB
1
speaker distance to the device: up to 3 m (9.8ft)
2
maximal speaker distance to the device: 2 to 3 cm (0.79in to 1.18in)
3
internal loudspeaker have to be disconnected
4
adjust chamber loudspeaker to the range of audibility