The device can be programmed according to customer-specic
requirements so that the heating/cooling system heats/cools your
residence or ofce to the required temperature at the dates and
times specied by you, to reduce energy costs while maintaining
comfort. Separate temperature programs can be prepared for
each day of the week. For each day, beside 1 xed switching time
(PROG ), 6 adjustable switching times (PROG – PROG ) can be
set (at 10-minute intervals) and a different temperature (in 0.5°C
increments) can be assigned to all 7 switching times.
The switching sensitivity of the thermostat can be set to ±0.1°C,
±0.2°C (default setting) or ±0.3°C. This gure means the
temperature difference between the adjusted value and the actual
temperature measured during the switching process. In case of the
±0.2°C switching sensitivity and heating mode for example, if the
set temperature is 20°C, then the device switches the boiler on at
3