MAx Advanced User Guide 62
Issue Number: 4 www.controltechniques.com
The drive will trip on I2t.AC if 10.58 > 100%, for the time specified in parameter 4.54 Motor Overload time limit. Refer to parameter 4.54.
The drive will trip on O.ht3 if 10.59 >85°C.
This bit parameter is set to indicate that either the SL.Er or dL.Er trip condition has occurred.
10.58
Motor I
2
T accumulator
ô
0.0 ~ 100.0
ð
%ROUni P0.40
10.59 SLM PCB temperature
ô
0~100
ð
°CROUni
10.60 SLM technology fault warning
ô
0~1
ð
RO Bit