Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Menu 0
Running
the motor
Optimisation
Macros
Advanced
Parameters
Technical
Data
Diagnostics
UL Listing
Information
122 Unidrive User Guide
www.controltechniques.com Issue Number: 9
9.5 Unidrive VTC macro differences
Only macros 1, 2, 3 and 5 can be used with Unidrive VTC.
The following highlights the macro terminal differences for Unidrive VTC.
Any terminal not listed below have the same function as open-loop
Unidrive.
Macros 1 and 5
Analog outputs 1 and 2 (terminals 9 and 10) are post ramp
frequency and total current outputs rather than speed and torque
outputs.
USA> Digital output F1 (terminal 24) is drive running indicator rather
than At speed.
Macros 2 and 3
Analog outputs 1 and 2 (terminals 9 and 10) are post ramp
frequency and total current outputs rather than speed and torque
outputs.
USA> Analog input 2 is configured as a 4-20mA input rather than a
voltage input.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Control Techniques Unidrive 1 Series and is the answer not in the manual?

Control Techniques Unidrive 1 Series Specifications

General IconGeneral
BrandControl Techniques
ModelUnidrive 1 Series
CategoryController
LanguageEnglish

Related product manuals