Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 4 / 21
easy
touch
OEB OES OGB OGS
Error
message
Error description
Possible cause or remedy
E03.128 Communication
failure between CM
and GM or between
GM and FC
Check cable connection GM to FC
FC defective
GM defective
For an explanation of the parameter xxx-yyy-zzz
see the end of 5.1 page 12
E03.zzz
-xxx-yyy
Other error variants
For an explanation of the parameter xxx-yyy-zzz
see the end of 5.1 page 12
E03.1 Fan malfunction
(excessive
temperature in the
motor winding)
thermoprotection
contact has tripped
Fan motor has excessive temperature in the
winding (over 165°C)
a) One phase is missing from the power connection
b) Fan motor is defective
c) One phase is not connected through from the
contactor
d) Microfuse F10 (6.3 A or 10 A for floor models)
has tripped
e) Thermoprotection contact in the motor winding
(bi-metallic strip) defective or interrupted
Burner speed (fan) not reached
Motor speed not reached
Speed sensor on the motor defective
Frequency converter defective (with single phase)
Frequency converter (FC) (=all 1 NPE appliances)
- Old hardware FC (above all appliances before
1.10.04 without gas module)
- Replace FC (5014001) (current version HW
26.11.26.11.04 / SW 1.2!)
- Update CM and OM software to the current
version (install 3.14 or above)
Wiring space temp. too high (but E02 is not being
displayed yet Check wiring space cooling
E04.0
ID=36
Auxiliary fan
malfunction
Motor current too
high etc.: threshold
of 1.5A (V1-V2)
Auxiliary fan fault
Auxiliary fan wiring interrupted
Auxiliary fan blocked
E05.0 No gas (after 2
ignition attempts no
confirmed gas
flame)
No gas or error in the burner system
Glow igniter defective (measure current approx. 1.2A)
Glow insert displaced in metal housing (replace
glow igniter)
Ionisation electrode defective
- Short circuit monitoring electrode (observe ignition
of the burner in the start phase; if flame was
present, circuit is the cause). Watch out for short
circuit between cable and housing in particular