Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 5 / 21
easy
touch
OEB OES OGB OGS
Error
message
Error description
Possible cause or remedy
- Burner stocking braid has a short circuit to earth to
the ionisation electrode
- Ionisation electrode cable is resting on earth
(in the burner or on motor cover)
Air in gas pipe
Gas tap closed
Input undervoltage (< 195 V) (appliance connected
via cable reel)
OGS/OGB 10.20/12.20/20.20 (and 20.10 only SG)
starts poorly/does not start after glow electrode
replacement
- Wrong glow igniter fitted: short instead of long;
correct is 4018001 = long (wrong is 4018002 =
short)
STL has triggered (test passage)
Burner fan is not running (visual inspection or in
speed actual value in the service programmes)
Interruption in monitoring electrode wiring
E05.1 No gas
B7.1 Safety temperature limiter for hot air has
triggered (test passage)
No gas at the burner HA1 (hot air1)
In addition same causes possible as with E05.0
E05.2 No gas
B7.2 Safety temperature limiter for steam generator
has triggered (test passage)
No gas at the burner SG (steam generator)
In addition same causes possible as with E05.0
E05.3 No gas
No gas at the burner HA2 (hot air2)
In addition same causes possible as with E05.0
E05.4-1 No gas
Start speed at the burner HA1 not reached
PWM signal interrupted
E05.4-2 No gas
Start speed at the burner HA1 not reached
Possibly voltage supply disturbed
E05.5-1 No gas
Start speed at the burner SG not reached
PWM signal interrupted
E05.5-2 No gas
Start speed at the burner SG not reached
Possibly voltage supply disturbed
E05.6-1 No gas
(only 20.10 / 20.20)
Start speed at the burner HA2 not reached
PWM signal interrupted
E05.6-2 No gas
(only 20.10 / 20.20)
Start speed at the burner HA2 not reached
Possibly voltage supply disturbed
E05.7-1 No gas
Full load speed at the burner HA1 not reached
PWM signal interrupted