Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 6 / 21
easy
touch
OEB OES OGB OGS
Error
message
Error description
Possible cause or remedy
E05.7-2 No gas
Full load speed at the burner HA1 not reached
Possibly voltage supply disturbed
E05.8-1 No gas
Full load speed at the burner SG not reached
PWM signal interrupted
E05.8-2 No gas
Full load speed at the burner SG not reached
Possibly voltage supply disturbed
E05.9-1 No gas
(only 20.10 / 20.20)
Full load speed at the burner HA2 not reached
PWM signal interrupted
E05.9-2 No gas
(only 20.10 / 20.20)
Full load speed at the burner HA2 not reached
Possibly voltage supply disturbed
E05.10 No gas
(from software 4.15)
Wait 20 seconds, if
there is no “Flame
OK” or “Alarm
Signal”
Interruption of Flame OK or Alarm Signal between
flame controller - control module HA1.
Check connection between FA and CM / GM:
CM (Control Module): for OGS 6.10 to OGS 12.20:
X14:1/2 and X15:12 (for appliances without GM)
GM (Gas Module): Plug X20:5/6 and X25:10
FA (Flame Controller): Terminals 1, 2, 5
E05.11 No gas
(from software 4.15)
Wait 20 seconds, if
there is no “Flame
OK” or “Alarm
Signal”
Interruption of Flame OK or Alarm signal between
flame controller - SG control.
Check connection between FA and GM:
GM (Gas Module): Plug X21:4/5 and X25:11
FA (Flame Controller): Terminals 1, 2, 5
E05.12 No gas
(from software 4.15)
Wait 20 seconds, if
there is no “Flame
OK” or “Alarm
Signal”
Interruption of Flame OK or Alarm signal between
flame controller - control module HA2.
Check connection between FA and GM:
GM (Gas Module): Plug X22:4/5 and X25:12
FA (Flame Controller): Terminals 1, 2, 5
E11.0
ID=23
Oven sensor (B6
thermoelement)
excessive
temperature
(temperature on the
sensor >300°C)
Hot air contactors do not switch off (burnt together)
Motor not operating (e.g. because of 2 defective
microfuses F10, not with the 6.06 as F10 protects
the CM).
E12.1
ID=25
Core temperature
sensor 1 - excessive
temperature
Temperature of CTS sensor already higher than the
maximum possible desired value (sensor not
inserted into food correctly)
E12.2
ID=26
Core temperature
sensor 2 - excessive
temperature
Temperature of CTS sensor already higher than the
maximum possible desired value (sensor not
inserted into food correctly)
E12.3
ID=27
Core temperature
sensor 3 - excessive
temperature
Temperature of CTS sensor already higher than the
maximum possible desired value (sensor not
inserted into food correctly)