Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 7 / 21
easy
touch
OEB OES OGB OGS
Error
message
Error description
Possible cause or remedy
E12.4
ID=28
Core temperature
sensor 4 - excessive
temperature
• Temperature of CTS sensor already higher than the
maximum possible desired value (sensor not
inserted into food correctly)
E13.0 Steam generator (B4
thermoelement)
Excessive
temperature (if
temperature
measured in the SG
>120°C)
• Foaming in the steam generator when cooking (due to
e.g. wrong, non-original CONVOTHERM cleaning
agents)
• Calcification of the steam generator
• Boiling dry of the immersion heaters due to double
level sensor's short circuit to earth
E15.0
ID=21
Condenser sensor
(B3- thermoelement)
excessive
temperature
(if temperature in
the condenser
measured > 100°C)
• Water reservoir in the condenser too hot:
a) Tap closed
b) Appliance connected to hot water
c) Solenoid valve “condenser cooling” defective
d) Coil from the solenoid “condenser cooling”
defective
e) Inlet filter in the solenoid valve contaminated
f) Quenching nozzle in the condenser/siphon blocked
E16
Demoisturisation
flap operating fault
(only 6.06)
• Demoisturisation flap faulty
a) Stiff
b) Motor contact
c) Motor defective
d) Flap blocked
e) Cable defects (contact / motor)
E21.0
ID=5
Oven sensor (B6-
thermoelement)
interruption
• Sensor wiring interrupted (plug X16 of the control
module)
• Oven sensor (B6) interrupted (defective)
E21.1
ID=14
Oven sensor B6 (in
front of fan) - Short
circuit to earth
• Thermoelement sensor (B6) has contact with
appliance housing
• Thermoelement (B6) defective
E22.0 Core temperature
sensor
(B10- thermoelement)
interruption (if more
than 2 measuring
points are interrupted)
• Sensor wiring interrupted (plug X16 of the control
module)
• CTS sensor (B10) interrupted (defective)
E22.1
ID=6
CTS1 core
temperature sensor
failure
(B10- thermoelement)
interruption
• Sensor wiring interrupted (plug X16 of the control
module)
• CTS sensor (B10) interrupted (more than 2
thermoelements defective)
E22.2
ID=7
CTS2 core
temperature sensor
failure
(B10- thermoelement)
interruption
• Sensor wiring interrupted (plug X16 of the control
module)
• CTS sensor (B10) interrupted (more than 2
thermoelements defective)