CX3G/FX3GC PLC Programming manual
www.coolmayplc.com
7
supported
Pointer
JUMP、CALL branch
P0~P2047
P0
~
P1280
2048 points
1281
points(26232 and
above)
CJ instruct、CALL instruct
Input interrupt
I0□□~I5□□
6points
Timer interrupt
I6□□~I8□□
3points
Nest
Master control
N0~N7
8points
MC instruct
Constant
Decimal (K)
16 bit
-32,768~+32,767
32 bit
-2,147,483,648~+2,147,483,647
Hexadecimal (H)
16 bit
0~FFFF
32 bit
0~FFFFFFFF
Real number(E)*3
32 bit
-1.0×2128~-1.0×2-126,0,1.0×2-126~1.0×2128
Can be in the form of a decimal point and index