4. Programming
496478 35
To change: Key-in: Notes Default
Downloader Tel No 1 118
YY
Maximum 31 digits
Downloader Tel No 2 119
YY
Maximum 31 digits
Fast Format channels 121
Y
a
Y
b
Y
For built in Communicator a is the channel number 1 to 8
b is one of the following:
0 Not Used
1 Fire Y
2PA Y
3 Burglar Y
4 Open/Close Y
5 Alarm Abort
6 Technical Alarm
7 Alarm Confirmation
8 RF Detector Low Battery
9 RF Supervision Loss
X1 Jamming
X2 AC Fail
X3 Tamper Alarm
X4 Open
X5 Close
X6 Zone Omitted
Restoral reporting 123
Y
0 Restore off Y
1 Restore on
Country 126
Y
nn
nn = country, one of:
0 = UK (Y) 5 = Italy 10 = Ireland
1 = NL 6 = Spain 11 = OEM 1
2 = Belg. (Flemish) 7 = Denmark 12 = OEM 2
3 = Belg. (French) 8 = Norway
4 = France 9 = Sweden/Finland
Note: If you carry out this command then the system will load all defaults for the
selected country.
Extended Report mode 131
Y
0 Basic Y
1 Summary
2 Intermediate
3 Full
SIA Tones 132
Y
0 Bell 103 Y
1 CCITT V21
CID Report Restorals 143
Y
0 Mode Basic Y
1 Mode Basic + Restore

Table of Contents