2. Programming Commands
497096, Issue 6 Page 13
Value Attribute Valid for Description
B Armed in
Level or
Partition B
All When applied, the zone is armed when the
user selects Level or Partition B.
C Armed in
Level or
Partition C
All When applied, the zone is armed when the
user selects Level or Partition C.
D Armed in
Level or
Partition D
All When applied, the zone is armed when the
user selects Level or Partition D.
For information on how zones behave in linked partitions, refer to "Common
Areas" on page 79.
Zones and Partitions
In a partitioned system, you can assign some zone types to two or more
partitions, and some zone types to one partition only.
One partition only More than one partition
Panic Alarm (PA)
Fire (FR)
24-hour (24)
Technical (TC)
Smoke Detector (SD)
Keyswitch – Momentary (KM)
Keyswitch – Fixed (KF)
Normal Alarm (NA)
Final Exit (FE)
Entry Route (ER)
Shock Analyser (SA)
Keybox (KB)
Anti-Mask (AM)
Forbikobler (FB)
Use those zone types that can be assigned to more than one partition to
create a common area (see page 79).
Some zone types are not assigned to a partition: AC Fail (AC), Low Battery
(LB), Battery Fault (BF) and Power Output Fault (PF). The Fault zone type
(FL) is always assigned to Partition A.
20: Change Engineer Code
Note: 9x5x control units support six-digit access codes as well as the standard four-digit
codes. Command 56 sets the code length.
To change the Engineer Code:
1. Make sure you are in installer mode.
2. Press 20y
The display shows:
20:Code