2. Programming Commands
497096, Issue 6 Page 19
37: Daytime Tamper Communication
This command defines how the control unit reports tamper indications (for
example, an attempt to open a control unit or keypad case) while the alarm
system is unset.
Option
0 Internal sounder only (default).
1 Internal sounder and communication of tamper indication to the Alarm
Receiving Centre (ARC).
Notes:
1. Compliance with PD 6662 / prEN 50131-1: 2004 (see page 86) at Grade 3 requires
that Command 37 is set to 1.
2. Command 31 sets user/engineer reset for zone tampers.
3. Command 38 sets user/engineer reset for system tampers.
4. Command 58 sets user/engineer reset for system tampers.
38: System Tamper User/Engineer Reset
This command defines how to reset the control unit after a tamper alarm (for
example, an attempt to open a control unit or keypad case).
To require an engineer reset, select option 1 (the default). To permit a user
reset (provided that no tamper circuit is open), select option 0.
Note: This facility is independent of the options selected in Commands 31 and 33.
39: Level/Partition A Exit Mode
Use this command to select the exit mode for Full Set or Partition A. The
keypads give a double "beep" confirmation tone at the end of all setting
modes, including Silent Set. The default is option 0, Timed.
In a single system, the options are:
Option
0 Timed. Use this option if the system sets after an exit time selected
using Command 44. If an Exit Terminate button is fitted, the user may
use it to shorten the exit time.
1 Terminated. Use this option if the user completes setting the system
by pushing an Exit Terminate button connected to a keypad. The exit
time is infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182 (see page 63).
2 Final Door Set. Use this option to complete setting of the system by
closing a door fitted with a Final Exit zone detector. The exit time is
infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182 (see page 63).

Table of Contents

Other manuals for Cooper Scantronic 9 5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cooper Scantronic 9 5 Series and is the answer not in the manual?

Cooper Scantronic 9 5 Series Specifications

General IconGeneral
BrandCooper
ModelScantronic 9 5 Series
CategoryControl Unit
LanguageEnglish

Related product manuals