2. Programming Commands
Page 20 497096, Issue 6
3 Lock Set. To use this option, you must install a lock switch and
connect its contacts to the ET terminals of a keypad (refer to the 9x5x
Installation Guide). This facility is available on keypad software
version 1.4.2 onwards. See the notes below for more information.
In a partitioned system, the options are:
Option
0 Timed. Use this option if the system sets after an exit time selected
using Command 44. If an Exit Terminate button is fitted, the user may
use it to shorten the exit time.
1 Terminated. Use this option if the user completes setting the system
by pushing an Exit Terminate button connected to a keypad. The exit
time is infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182.
2 Final Door Set. Use this option to complete setting of the system by
closing a door fitted with a Final Exit zone detector. The exit time is
infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182.
3 Instant Set (no exit tone). Use this option to make the system set
without delay or exit tone.
4 Silent Set. Use this option to make the system set without an exit
tone. Use Command 44 to program the exit time.
5 Lock Set. To use this option, you must install a lock switch and
connect its contacts to the ET terminals of a keypad (refer to the 9x5x
Installation Guide). This facility is available on keypad software
version 1.4.2 onwards. See the notes below for more information.
Notes on Lock Set:
1. Do not assign the keypad to more than one partition. Do not connect more than one
lock switch (or any other device) to the keypad ET terminals. In a single system, do
not attempt to fit two lock switches.
2. To set the system, the user first enters their access code at a keypad or operates a
keyswitch. The control unit starts to emit the exit tone. The exit time is infinite in this
option. The user then operates the Final Exit zone and turns the key in the lock
switch to "locked". The system sets 7–12 seconds after the lock switch contacts
open; the delay is set with Command 182 (see page 63).
3. To unset the system, the user turns the lock switch to "unlocked" (which closes the
contacts). The keypads start to emit a continuous tone; this is not affected by
PD6662 / pr EN 50131-1: 2004, as the possession of a key indicates an authorised
user. At this point, the user can lock the lock switch again without causing an alarm.
When the user opens the Final Exit zone, the control unit starts the entry timer. The
user completes entry by unsetting the system in the normal way.
4. When the user unlocks the lock switch, the control unit disables Alarm
Confirmation. If the user locks the lock switch without starting the entry timer, the
control unit enables Alarm Confirmation again.