4. System Configurations
Page 84 497096, Issue 6
DD243: 2004 Compliance
Applicability
Please study this section if all of the following apply:
1. You are installing an alarm system in England, Wales or Northern Ireland.
2. The system has remote signalling and requires the local Police Authority to
issue a URN (Unique Reference Number).
3. You have chosen to use "Sequential Alarm Confirmation" to comply with
DD243: 2004.
For Installers in Scotland, the ACPOS-IAS policy document states:
"Confirmation technology (BS DD243 applies) is desirable for newly installed
systems but is not mandatory in terms of this policy."
Cooper Security therefore recommends that systems in Scotland are installed
to comply with DD243: 2004, and Installers obtain copies of the ACPOS policy
from their local Police Authority.
Note: The installed system will only fully comply with the requirements of DD243: 2004 if it
has been designed in accordance with this section.
Programming for Compliance
Use the following settings to ensure compliance with DD243: 2004. The table
below summarises which options to select for various commands in order to
comply with paragraphs 6.4.2 to 6.4.6.
DD243: 2004 Para, and Possible Installation
6.4.2 6.4.3 6.4.4 6.4.5 6.4.6
Command
Unset from
outside the
premises
using a
keyswitch
zone input
entry must
be prevented
until system
is unset
Exit Mode of
"Lock Set"
Keypad and
user access
code
Portable
ancillary
control
equipment –
with the
reader inside
the premises
Requires
ARC to
unset
33 System Reset Engineer (Option 1)
89 Alarm Confirmation DD243 (Option 1)
160 Confirmation Time 30 to 60 minutes
48 Lockout Keypads
During Entry
No
(Option 0)
No
(Option 0)
No
(Option 0)
Yes
(Option 1)
No
(Option 0)
163 Confirmation on
Entry
Never
(Option 0)
Never
(Option 0)
Never
(Option 0)
Two zones
(Option 2)
Never
(Option 0)

Table of Contents

Other manuals for Cooper Scantronic 9 5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cooper Scantronic 9 5 Series and is the answer not in the manual?

Cooper Scantronic 9 5 Series Specifications

General IconGeneral
BrandCooper
ModelScantronic 9 5 Series
CategoryControl Unit
LanguageEnglish

Related product manuals