Technical Support Manual 05/2018 Rel. 2.1.3 Page 12
To activate or deactivate the width sensor, proceed as follow.
Description
1
Enter the SERVICE mode by pressing [F+P3]
.
2
Press [F+P5] to
enter in PARAMETERS MENU.
3
A password is required to enter this menu.
Enter the password by pressing the keys in
the sequence indicated within 5 seconds, or
the machine will return to SERVICE mode:
1. [P1]
2. [P4]
3. [P2]
4. [P5]
4
Browse the list of the menus with [P4]
or [P5] until the option
required is displayed.
5
Press [F+P5] to
activate the WIDTH SENSOR GAUGE. The
WIDTH SENSOR GAUGE IS ENABLED. To
deactivate the WIDTH SENSOR GAUGE press
again [F+P5] .
6
To exit the Parameters Menu, select option
Ret and press [F+P5]
.
The deactivation of the width sensor has no effect on the automatic acquisition of distance and diameter.